<!– /* Font Definitions */ @font-face {font-family:”Cambria Math”; panose-1:2 4 5 3 5 4 6 3 2 4; mso-font-charset:1; mso-generic-font-family:roman; mso-font-format:other; mso-font-pitch:variable; mso-font-signature:0 0 0 0 0 0;} @font-face {font-family:Calibri; panose-1:2 15 5 2 2 2 4 3 2 4; mso-font-charset:0; mso-generic-font-family:swiss; mso-font-pitch:variable; mso-font-signature:-1610611985 1073750139 0 0 159 0;} /* Style Definitions */ p.MsoNormal, li.MsoNormal, div.MsoNormal {mso-style-unhide:no; mso-style-qformat:yes; mso-style-parent:””; margin-top:0in; margin-right:0in; margin-bottom:10.0pt; margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:”Calibri”,”sans-serif”; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:Calibri; mso-fareast-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:”Times New Roman”; mso-bidi-theme-font:minor-bidi;} .MsoChpDefault {mso-style-type:export-only; mso-default-props:yes; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:Calibri; mso-fareast-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:”Times New Roman”; mso-bidi-theme-font:minor-bidi;} .MsoPapDefault {mso-style-type:export-only; margin-bottom:10.0pt; line-height:115%;} @page Section1 {size:8.5in 11.0in; margin:1.0in 1.0in 1.0in 1.0in; mso-header-margin:.5in; mso-footer-margin:.5in; mso-paper-source:0;} div.Section1 {page:Section1;} –>
Author
B S Badmus1, E A Ayolabi2, J A Olowofela3, S A Adisa1 and T O Oyekunle1
Affiliations
1 Department of Physics, University of Agriculture, Abeokuta, Nigeria
2 Department of Physics, University of Lagos, Akoka, Lagos, Nigeria
3 Department of Physics, University of Ibadan, Ibadan, Nigeria
Abstract
Schlumberger and Wenner vertical electrical soundings (VES) were carried out at five locations each within the campus of University of Agriculture, Abeokuta, Nigeria, with the aim of imaging the subsurface using different current values varying from 0.2 A to 20.0 A at each location as it appears on an ABEM SAS300B terrameter. The results of the interpretation for both electrode arrangements revealed six geo-electric layers: topsoil, sandy clay, clayey sand, sandstone, shale/clay and fresh basement. The work revealed that a current range of 0.2–1.0 A is ideal for both Schlumberger and Wenner arrays in a basement terrain.